Victron Smallbms F/Smart Lifepo4 Batteries W/M8
Condition: New
Free Ground Shipping*
Victron Smallbms F/Smart Lifepo4 Batteries W/M8
SmallBMS for Smart LiFePO4 Batteries with M8
A simple and low-cost alternative to the VE.Bus BMS. The smallBMS can replace the VE.Bus BMS in several applications. It is however not suitable for use with VE.Bus MultiPlus and Quattro inverter/chargers: it has no VE.Bus interface.
The smallBMS is intended for use with Victron Smart LiFePo4 batteries with M8 circular connectors. The smallBMS has three outputs, similar to the VE.Bus BMS. Load Disconnect output The Load output is normally high and becomes free-floating in case of the cell under voltage (default 2,8V/cell, adjustable on the battery between 2,6V and 2,8V per cell). Maximum current: 1A. The Load output is not short-circuit protected.
The Load output can be used to control:
- A high current relay or contactor.
- The remote on/off the input of a Battery Protect, inverter or DC-DC converter, or other loads.
Pre-alarm output
The pre-alarm output is normally free-floating and becomes high in case of the imminent cell under voltage (default 3,1V/cell, adjustable on the battery between 2,85V and 3,15V per cell). Maximum current: 1A (not short circuit protected).
The minimum delay between pre-alarm and load disconnect is 30 seconds.
Charge disconnect output
The Charger output is normally high and becomes free-floating in case of imminent cell overvoltage or over-temperature. Maximum current: 10mA. The Charger output is not suitable to power an inductive load such as a relay coil.
The Charger output can be used to control:
- The remote on/off of a charger
- A Cyrix-Li-Charge relay
- A Cyrix-Li-ct Battery Combiner
System on/off input
The system on/off input controls both outputs. When off, both outputs will be free floating so that loads and chargers are turned off. The System on/off consists of two terminals: Remote L and Remote H. A remote on/off switch or relay contact can be connected between L and H. Alternatively, terminal H can be switched to battery plus, or terminal L can be switched to battery minus.
Protects 12V, 24V and 48V systems
Operating voltage range: 8 to 70V DC.
LED indicators:
- Load ON (blue): Load output high (cell voltage >2.8V, adjustable on the battery).
- Temp or OVP (red): Charger output free floating (due to cell over temperature (>50°C), cell under temperature (<5 °C) or cell over voltage).
Manufacturer Part Number: BMS400100000
Special Shipping Message | Free Ground Shipping* |
---|---|
Manufacturer Part Number: | BMS400100000 |
Return Policy
Hodges Marine accepts returns for up to thirty (30) days after shipment. Our return policy does not apply to the following goods: Open software, mapping/chart data cards, international orders, freight truck only items, and special order items. These items are not eligible for return, refund or exchange. Shipping charges (if any) are non-refundable. If your return is accepted by Us, We will provide one of the following within a reasonable time: an exchange of merchandise for the item returned, a non-transferable merchandise credit, a credit to the payment card or original method of payment used to pay for the item, a check, or another remedy that we determine in good faith is appropriate in the circumstances. Customer must request a return merchandise authorization (RMA) through the product returns link on our website or by emailing us at [email protected]. A RMA number will be issued with instructions for returning the package within a reasonable time (normally 1-3 business days).